Adrbog.com DanskEnglishFrançais — coming soonDeutsch — coming soon ADR 2025 Reference Tool
Lite Pro
Hazard label 9
UN 3257

ELEVATED TEMPERATURE LIQUID, N.O.S., at or above 100 °C and below its flash-point (including molten metals, molten salts, etc.), filled at a temperature higher than 190 °C

ADR 2025 · Class 9 · 2 variants · carriage of dangerous goods by road

Class
9
Classif.
M9
Pack. group
III
Hazard labels
9
Transport cat.
3 (D)

Variant 1 — packing group III

Class
9
Classification code
M9
Packing group
III
Hazard labels
9 Hazard label 9
Special provisions
274 643 668
Limited quantities
0
Excepted quantities
E0
Packing instructions
P099 IBC99
Tank instruction
T3
Special tank
TP3 TP29
Tank code
LGAV
Special tank code
TU35 TC7 TE6 TE14 TE18 TE24
Vehicle type
AT
Transport category
3 (D)
Special carriage
VC3 AP11
Hazard number
99
Exemption limit
1000 kg/L

Variant 2 — packing group III: ELEVATED TEMPERATURE LIQUID, N.O.S., at or above 100 °C and below its flash-point (including molten metals, molten salts, etc.), filled at or below 190 °C

Class
9
Classification code
M9
Packing group
III
Hazard labels
9 Hazard label 9
Special provisions
274 643 668
Limited quantities
0
Excepted quantities
E0
Packing instructions
P099 IBC99
Tank instruction
T3
Special tank
TP3 TP29
Tank code
LGAV
Special tank code
TU35 TC7 TE6 TE14 TE24
Vehicle type
AT
Transport category
3 (D)
Special carriage
VC3
Hazard number
99
Exemption limit
1000 kg/L

Special provisions

SP 274

The provisions of 3.1.2.8 apply.

SP 643

Stone or aggregate asphalt mixture is not subject to the requirements for Class 9.

SP 668

Substances for the purpose of applying road markings and bitumen or similar products for the purpose of repairing cracks and crevices in existing road surfaces, carried at elevated temperature, are not subject to the requirements of ADR, provided that the following conditions are met: (a) They do not fulfil the criteria of any class other than Class 9; (b) The temperature of the outer surface of the boiler does not exceed 70 °C; (c) The boiler is closed in such a way that any loss of product is prevented during carriage; (d) The maximum capacity of the boiler is limited to 3 000 l.

Related substances in Class 9